Digital Multifunctional Process Calibrator Millivolt and Volt Testing and Simulating TC and RTD Signals
Asin: B07FBY126B | Model: HT824 | PartNumber: HT824
As an Amazon Associate we earn a fee from qualifying purchases when you follow a link to Amazon from this page. We rank the products, but the links to Amazon are promotional.Test Or Simulate Kinds Of Tc And Rtd Signals.
Auto Power Off When The Voltage Of Battery Is Low.
Manual/Auto Cold Junction Compensation And Setting.
Simulate To Output Voltage In Millivolt And Volt.
Features
- High Accuracy Multifunctional Process Calibrator
- Simulate to output voltage in millivolt and volt
- Test or simulate kinds of TC and RTD signals
- Manual/auto cold junction compensation and setting
- Auto power off when the voltage of battery is low
- See more on Amazon...
Brand: MUW | Manufacturer: MUW
Dimensions: 5.91 x 7.28 x 1.06 Inches | Weight: 0.77 Pounds
See On Amazon Similar To Digital Multifunctional Process Calibrator Millivolt
#1
ennoLogic Volt mA Thermocouple Loop Process Calibrator eC370T - 0-20V and 4-20mA Simulator Portable Millivolt mA and Temperature Signal Generator and Meter for Transmitters, Current Loops, PLC
Asin: B083TPZ83X | Model: eC370T | PartNumber: eC370T
Measure Voltage Output Signals From Process Devices And Sensors With Two Input Ranges Of 0-100Mv (0.01Mv Resolution, 0.06% Accuracy) And 0-20V (1Mv Resolution, 0.08% Accuracy). Measure Current Transmitters Within A Range Of 0 To 24Ma With 0.001Ma Resolution And 0.08% Accuracy. Measure Thermocouple Temperatures Within A Range Of -250°C To +1800°C And Resolution Of ±0.7°C To ±2°C (Range And Resolution Depends On Thermocouple Type, Supported Are Type K, J, E, T, N, S, R, And B.).
The Ec370t Volt/Ma/Tc Calibrator Is Powered By Six Aaa Batteries (Included). A Windows-Based Software Tool Is Available For Download To Control The Calibrator With A Computer Via Usb Cable. The Package Includes One Ec370t Calibrator, 6 Aaa Batteries, Carrying Case, Test Leads, Alligator Clip Adaptors For Test Leads, Type K Thermocouple Probe, K-Type Thermocouple Connector, Mini-Usb Cable And A Detailed User Manual..
Generate Precise Test Voltages, Currents And Simiulated Thermocouple Temperature Signals For Testing Loops, Transmitters, Data Loggers, Meters Or Any Devices That Measure 4-20Ma Currents, Sensor Voltages, Or Temperatures. Generate Voltages In Two Ranges: 0-100Mv (0.01Mv Resolution) And 0-20V (1Mv Resolution). Generate Currents Within A Range Of 0 To 24Ma (0.001Ma Resolution). Generate Thermocouple Temperature Signals Within A Range Of -250°C To +1800°C (For Types K, J, E, T, N, S, R, And B)..
Numeric Keypad For Ease And Flexibility In Setting Output Signals Configuring Options. Hotkey Programming For Each Numeric Key (Long-Press Immediately Outputs User-Configured Voltage, Current Or Temperature Signal). Ramp And Ladder Output Functions Can Be Custom Configured. Built-In 24V Loop Supply Lets You Power And Read A Device Or Transmitter Without Needing Another Multimeter. This Greatly Simplifies Testing 2-Wire Current Loops..
Features
- VERSATILE AND ACCURATE VOLT MA THERMOCOUPLE CALIBRATOR: Signal generator, simulator and volt / mA meter for calibrating, testing and repairing milliamp loops, thermocouples, PLC, temperature control and HVAC systems. Easily generate precise test signals for current and voltage devices (mA, mV, V, Celsius and Fahrenheit ranges).
- NUMERIC KEYPAD for ease and flexibility in setting output signals configuring options. HOTKEY programming for each numeric key (long-press immediately outputs user-configured voltage, current or temperature signal). RAMP AND LADDER OUTPUT FUNCTIONS can be custom configured. BUILT-IN 24V LOOP SUPPLY lets you power and read a device or transmitter without needing another multimeter. This greatly simplifies testing 2-wire current loops.
- MEASURE VOLTAGE OUTPUT SIGNALS from process devices and sensors with two input ranges of 0-100mV (0.01mV resolution, 0.06% accuracy) and 0-20V (1mV resolution, 0.08% accuracy). MEASURE CURRENT TRANSMITTERS within a range of 0 to 24mA with 0.001mA resolution and 0.08% accuracy. MEASURE THERMOCOUPLE TEMPERATURES within a range of -250 C to +1800 C and resolution of 0.7 C to 2 C (range and resolution depends on thermocouple type, supported are type K, J, E, T, N, S, R, and B.)
- GENERATE PRECISE TEST VOLTAGES, CURRENTS AND SIMIULATED THERMOCOUPLE TEMPERATURE SIGNALS for testing loops, transmitters, data loggers, meters or any devices that measure 4-20mA currents, sensor voltages, or temperatures. Generate voltages in two ranges: 0-100mV (0.01mV resolution) and 0-20V (1mV resolution). Generate currents within a range of 0 to 24mA (0.001mA resolution). Generate thermocouple temperature signals within a range of -250 C to +1800 C (for types K, J, E, T, N, S, R, and B).
- The eC370T Volt/mA/TC calibrator is powered by six AAA batteries (included). A windows-based software tool is available for download to control the calibrator with a computer via USB cable. The package includes one eC370T calibrator, 6 AAA batteries, carrying case, test leads, alligator clip adaptors for test leads, Type K thermocouple probe, K-Type thermocouple connector, Mini-USB cable and a detailed user manual.
- See more on Amazon...
Brand: ennoLogic | Manufacturer: Cascadia Innovations
See On Amazon #2
Handheld Loop Calibrator
Asin: B0BPYK2J2V | Model: MP700005 | PartNumber: MP700005 | Ean: 0713179650418 | UPC: 713179650418
Output Functions: Dc Current, Analog Transmitter, 24V Loop.
Automatic Ramp For Dc Current Output.
Provides 24V Loop Power To Transmitter While Conducting Ma Current Measurement At The Same Time.
Supplied With Pp3 Battery.
Stores And Recalls Setup.
Manual Stepping, Automating Stepping And Ramping Output.
Features
- Measures: DC voltage, DC current, 4-20mA loop current
- Manual stepping, automating stepping and ramping output
- Output functions: DC current, analog transmitter, 24V loop
- Stores and recalls setup
- Provides 24V loop power to transmitter while conducting mA current measurement at the same time
- Supplied with PP3 battery
- Automatic ramp for DC current output
- See more on Amazon...
Brand: multicomp PRO | Manufacturer: Multicomp Pro
Weight: 0.00 Pounds
Warranty: 1 Year Warranty
See On Amazon #3
Precision Multi-Function Calibrator TD1850 High Accuracy 0.05 Class, AC/DC Voltage/Current Output, 3.5 Digit Multimeter Calibration Tool for Industrial and Laboratory Use
Asin: B0CZRQHBDM | Ean: 0658361268500 | UPC: 658361268500
Wide Output Range: The Multi-Function Calibrator Has A Wide Output Range From Millivolts To Kilovolts, Microamps To Tens Of Amps, Which Can Meet Various Equipment And Measurement Requirements And Is Suitable For Different Industries And Environments..
Efficient Calibration Process: The Multifunctional Calibrator Simplifies Calibration With Direct Output Settings And Precise Adjustments. The Remote Adjustment Feature Enables Fine-Tuning Of Current Or Voltage, While The Knob Mode Provides Convenient Adjustment Options To Increase Efficiency And Accuracy During Calibration Tasks..
User-Friendly Operation: The Td1850 Multifunction Calibrator Ensures Ease Of Use With Multiple Output And Adjustment Methods, Including Direct Output Via Physical Keys Or Touch Screen, As Well As Remote Adjustment Options. Touchscreen Calibration Point Adjustment And Knob Mode Further Enhance Usability..
Multi-Function: The Multi-Function Calibrator Integrates Ac/Dc Voltage Source, Ac/Dc Current Source And Dc Resistance Source. It Also Provides 2 Mhz Square Wave Frequency Output, Remote Adjustment, Clamp Meter Calibration, Sensor Calibration And Other Optional Functions To Meet Different Calibration Needs..
Features
- Precision Calibration: The TD1850 multifunction calibrator has an accuracy rating of 0.05, making it ideal for precise calibration of 3.5-digit digital multimeters. The DC voltage output range is 20 mV to 1100 V, the DC current output range is 2 A to 22 A (33 A optional), and the AC voltage/current output covers a similar range to ensure accurate measurements.
- Multi-function: The multi-function calibrator integrates AC/DC voltage source, AC/DC current source and DC resistance source. It also provides 2 MHz square wave frequency output, remote adjustment, clamp meter calibration, sensor calibration and other optional functions to meet different calibration needs.
- Wide output range: The multi-function calibrator has a wide output range from millivolts to kilovolts, microamps to tens of amps, which can meet various equipment and measurement requirements and is suitable for different industries and environments.
- User-Friendly Operation: The TD1850 multifunction calibrator ensures ease of use with multiple output and adjustment methods, including direct output via physical keys or touch screen, as well as remote adjustment options. Touchscreen calibration point adjustment and knob mode further enhance usability.
- Efficient calibration process: The multifunctional calibrator simplifies calibration with direct output settings and precise adjustments. The remote adjustment feature enables fine-tuning of current or voltage, while the knob mode provides convenient adjustment options to increase efficiency and accuracy during calibration tasks.
- See more on Amazon...
Brand: GOYOJO | Manufacturer: GOYOJO
See On Amazon #4
GuliTech Victor/RuoShui Multifunction Calibration 24 Handheld Multifunction Process Calibrator 0.02% Accuracy Measurement Source Temperature Monitoring Function calibrator(Victor 24)
Asin: B0CKP59GR5 | Model: G-VICTOR 24 | PartNumber: G-VICTOR 24
Measurement/Source Temperature Monitoring Function.
The Lcd Screen Is Divided Into Two Separate Districts.
Measurement Manual-Holding Function Pressure Source Auto-Holding Function.
Tc Measurement/Source Terminals And Built-In Lead Connector Of Same Temperature.
Features
- You can operate the measurement and source function simultaneously.
- TC measurement/source terminals and built-in lead connector of same temperature
- Measurement/source temperature monitoring function
- Measurement manual-holding function Pressure source auto-holding function
- The LCD screen is divided into two separate districts
- See more on Amazon...
Brand: GuliTech | Manufacturer: Victor
Dimensions: 4.72 x 8.66 x 5.91 Inches | Weight: 1.10 Pounds
Warranty: 1 year warranty
See On Amazon #5
Digital Outside Micrometer, 1"-2" Measurement Range, 0.00005" Increment, Cast Iron Frame
Asin: B0BQZFWJZ7
Measurement Increment: 0.00005".
Container: Plastic Case.
Includes: Batteries, Calibration Standard, Spanner.
Measurement Range: 1"-2".
Features
- General purpose micrometers used for precisely measuring external dimensions
- Measurement Range: 1-2
- Measurement Increment: 0.00005
- Includes: Batteries, Calibration Standard, Spanner
- Container: Plastic Case
- See more on Amazon...
Brand: CME Tools | Manufacturer: CME Tools
See On Amazon #6
VC24 Multi-Function calibratorProcessInstrument calibratorLoopProcess Calibrator Thermocouple
Asin: B0BNXJKPBH | Ean: 0797447585664 | UPC: 797447585664
Features
- VC24 multi-function calibratorProcessInstrument calibratorLoopProcess Calibrator Thermocouple
- See more on Amazon...
Brand: VIHELM | Manufacturer: VIHELM
See On Amazon #7
Universal Process Calibrator Measuring Current, Resistance, Voltage for Calibration of Process Control Instruments, Temperature & Pressure Transmitters, Flow Transmitters | Model: BTH C9
Asin: B09JSJYY3Y
Ac Voltage Measurement: Range: 400.0Mv, Resolution: 0.1Mv, Accuracy: 1.0% + 4; Range: 4.000V, Resolution: 0.001V, Accuracy: 0.5% + 4; Range: 40.00V, Resolution: 0.01V, Accuracy: 0.5% + 4; Range: 400.0V, Resolution: 0.1V, Accuracy: 0.5% + 4; Dc Current Measurement: Range: 40.00Ma, Resolution: 0.01Ma, Accuracy: 0.2% + 4; Range: 400.0Ma, Resolution: 0.1Ma, Accuracy: 0.2% + 4.
Power Supply: 6V Batteries (4*1.5V Alkaline Aaa Batteries Or 4*1.5V Ni-Mh Aaa Batteries); Maximum Voltage: 600Vp-P (Maximum Voltage Between All Input Jacks & Earth Ground), 30V Dc (Maximum Voltage Between All Output Jacks & Earth Ground); Accessories: A Copy Of User Manual, A Set Of Industrial Test Lead (With Alligator) Clips And Two 63Ma/250V Fast-Blow Fuses; Safety: Compiled With Iec61010 (Safety Standard Issued By International Electro-Technical Commission..
Ac Current Measurement: Range: 40.00Ma, Resolution: 0.01Ma, Accuracy: 0.5% + 4; Range: 400.0Ma, Resolution: 0.1Ma, Accuracy: 0.5% + 4; Operating Temperature: 5°C To 50°C; Operating Relative Humidity: <80% Rh, Storage Temperature: -10°C To 55°C, Storage Humidity: < 90% Rh.
Process Meter Measurements: Range: Dc Voltage Measurement: Range: 4.000V, Resolution: 0.001V, Accuracy: 0.2% + 4; Range: 40.00V, Resolution: 0.01V, Accuracy: 0.2% + 4; Range: 400.0V, Resolution: 0.1V, Accuracy: 0.2% + 4; Dc Mv Measurement: Range: 40.00Mv, Resolution: 0.01Mv, Accuracy: 0.5% + 6; Range: 400.0Mv, Resolution: 0.1Mv, Accuracy: 0.2% + 4.
Features
- Measuring Parameters: Frequency, OHM, Analog Transducer, DC mA, RTD, Thermocouples, Resistance, RTD Measurement, TC Measurrement, Frequency Count, Diode Test & Continuity Test.
- Process Meter Measurements: Range: DC Voltage Measurement: Range: 4.000V, Resolution: 0.001V, Accuracy: 0.2% + 4; Range: 40.00V, Resolution: 0.01V, Accuracy: 0.2% + 4; Range: 400.0V, Resolution: 0.1V, Accuracy: 0.2% + 4; DC mV Measurement: Range: 40.00mV, Resolution: 0.01mV, Accuracy: 0.5% + 6; Range: 400.0mV, Resolution: 0.1mV, Accuracy: 0.2% + 4
- AC Voltage Measurement: Range: 400.0mV, Resolution: 0.1mV, Accuracy: 1.0% + 4; Range: 4.000V, Resolution: 0.001V, Accuracy: 0.5% + 4; Range: 40.00V, Resolution: 0.01V, Accuracy: 0.5% + 4; Range: 400.0V, Resolution: 0.1V, Accuracy: 0.5% + 4; DC Current Measurement: Range: 40.00mA, Resolution: 0.01mA, Accuracy: 0.2% + 4; Range: 400.0mA, Resolution: 0.1mA, Accuracy: 0.2% + 4
- AC Current Measurement: Range: 40.00mA, Resolution: 0.01mA, Accuracy: 0.5% + 4; Range: 400.0mA, Resolution: 0.1mA, Accuracy: 0.5% + 4; Operating Temperature: 5 C to 50 C; Operating Relative Humidity: <80% RH, Storage Temperature: -10 C to 55 C, Storage Humidity: < 90% RH
- Power Supply: 6V batteries (4*1.5V alkaline AAA batteries or 4*1.5V Ni-MH AAA batteries); Maximum Voltage: 600Vp-p (Maximum Voltage between all input jacks & earth ground), 30V DC (Maximum Voltage between all output jacks & earth ground); Accessories: A copy of user manual, a set of industrial test lead (with alligator) clips and two 63mA/250V fast-blow fuses; Safety: Compiled with IEC61010 (Safety standard issued by International Electro-technical commission.
- See more on Amazon...
Brand: Ace Instruments | Manufacturer: Ace Instruments
See On Amazon #8
Graigar MS7218 Digital Portable Volt mA Process Calibrator 0.02% Accuracy
Asin: B07FNZXQXD | Ean: 0705419446288 | UPC: 705419446288
Simultaneous Ma And % Readout For Quick, Easy Interpretation Of Readings..
Innovative Output Adjustment Dial With 1 Μa And 100 Μa Resolution..
1 Μa Resolution For Ma Source, Simulate And Measure..
Ma Accuracy Of 0.025%, Superior To Other Loop Calibrators In This Price Range..
Features
- Large display and simple, quick-click interface for easy one-handed operation.
- mA accuracy of 0.025%, superior to other loop calibrators in this price range.
- Simultaneous mA and % readout for quick, easy interpretation of readings.
- 1 A resolution for mA Source, Simulate and Measure.
- Innovative output adjustment dial with 1 A and 100 A resolution.
- See more on Amazon...
Brand: Graigar | Manufacturer: Graigar
See On Amazon #9
General Tools Digital/Fraction Electronic Calipers, 0-8 in, Stainless Steel
Asin: B076VQRG78 | Ean: 0714637833268 | UPC: 714637833268
Brand: General Tools | Manufacturer: General Tools
See On Amazon
Looking For Something Else?
Search