CNYST Stormer Viscosity Tester Digital Stormer Viscometer with Measurement Range 40.2~141.0KU Measurement Accuracy 1.50% of Full Range Container Capacity About 500ml
Asin: B0D1Y3BVNF | Model: 2024041702 | PartNumber: 2024041702
As an Amazon Associate we earn a fee from qualifying purchases when you follow a link to Amazon from this page. We rank the products, but the links to Amazon are promotional.◆ The Temperature In The Laboratory Should Be 23 °C + 2 °C, And The Relative Humidity Should Be Less Than 75%..
◆ The Stom Viscometer Is Used For The Determination Of Paint And Other Ku Indicating The Viscosity Of The Coating. The Instrument Can Display The Ku Value Of The Measured Sample Viscosity Or The Load Value Associated With The Ku Value (Unit: G)..
◆ In Order To Ensure The Safety Of The Operator, The Power Outlet In The Laboratory Should Be Grounded Reliably;.
Features
- The instrument should be placed on a strong and smooth surface away from strong airflow, strong magnetic field, strong electric field and strong electric pulse interference.
- In order to ensure the safety of the operator, the power outlet in the laboratory should be grounded reliably;
- The temperature in the laboratory should be 23 C + 2 C, and the relative humidity should be less than 75%.
- The stom viscometer is used for the determination of paint and other KU indicating the viscosity of the coating. The instrument can display the KU value of the measured sample viscosity or the load value associated with the KU value (unit: G).
- See more on Amazon...
Brand: CNYST | Manufacturer: CNYST
See On Amazon Similar To CNYST Stormer Viscosity Tester Digital
#1
CNYST Stormer Viscosity Meter Tester Viscometer Testing Measuring for Paint with Measurement Range 40.2 to 141.0KU Accuracy 2.0% of Full Range
Asin: B07MGTDKGZ | Model: Viscosímetro | PartNumber: Viscosímetro | Ean: 0652054888754 | UPC: 652054888754
◆ The Temperature In The Laboratory Should Be 23 °C + 2 °C, And The Relative Humidity Should Be Less Than 75%..
◆ The Stom Viscosimeters Is Used For The Determination Of Paint And Other Ku Indicating The Viscosity Of The Coating. The Instrument Can Display The Ku Value Of The Measured Sample Viscosity Or The Load Value Associated With The Ku Value (Unit: G)..
◆ In Order To Ensure The Safety Of The Operator, The Power Outlet In The Laboratory Should Be Grounded Reliably;.
Features
- The Viscosimeters should be placed on a strong and smooth surface away from strong airflow, strong magnetic field, strong electric field and strong electric pulse interference.
- In order to ensure the safety of the operator, the power outlet in the laboratory should be grounded reliably;
- The temperature in the laboratory should be 23 C + 2 C, and the relative humidity should be less than 75%.
- The stom Viscosimeters is used for the determination of paint and other KU indicating the viscosity of the coating. The instrument can display the KU value of the measured sample viscosity or the load value associated with the KU value (unit: G).
- See more on Amazon...
Brand: CNYST | Manufacturer: CNYST
Dimensions: 19.69 x 8.27 x 7.09 inches | Weight: 28.66 Pounds
See On Amazon #2
CNYST Stormer Viscosity Meter Tester Stormer Rotational Viscometers with Measurement Range 40.2~141.0KU 27cP-5250cP for The Determination of Paint and Other KU Indicating The Viscosity of The Coating
Asin: B0D1XZSCB8 | Model: 2024041701 | PartNumber: 2024041701
◆ The Temperature In The Laboratory Should Be 23 °C + 2 °C, And The Relative Humidity Should Be Less Than 75%..
◆ The Stom Viscometer Is Used For The Determination Of Paint And Other Ku Indicating The Viscosity Of The Coating. The Instrument Can Display The Ku Value Of The Measured Sample Viscosity Or The Load Value Associated With The Ku Value (Unit: G)..
◆ In Order To Ensure The Safety Of The Operator, The Power Outlet In The Laboratory Should Be Grounded Reliably;.
Features
- The instrument should be placed on a strong and smooth surface away from strong airflow, strong magnetic field, strong electric field and strong electric pulse interference.
- In order to ensure the safety of the operator, the power outlet in the laboratory should be grounded reliably;
- The temperature in the laboratory should be 23 C + 2 C, and the relative humidity should be less than 75%.
- The stom viscometer is used for the determination of paint and other KU indicating the viscosity of the coating. The instrument can display the KU value of the measured sample viscosity or the load value associated with the KU value (unit: G).
- See more on Amazon...
Brand: CNYST | Manufacturer: CNYST
See On Amazon #3
CNYST Stormer Viscosity Tester Digital Stormer Viscosity Meter for The Determination of Paint and Other KU Indicating The Viscosity of The Coating Measurement Range 40.2~141.0KU 27cP-5250cP 32~1099g
Asin: B0D1VBVCMH | Model: 2024401606 | PartNumber: 2024401606
◆ The Temperature In The Laboratory Should Be 23 °C + 2 °C, And The Relative Humidity Should Be Less Than 75%..
◆ The Stom Viscosimeters Is Used For The Determination Of Paint And Other Ku Indicating The Viscosity Of The Coating. The Instrument Can Display The Ku Value Of The Measured Sample Viscosity Or The Load Value Associated With The Ku Value (Unit: G)..
◆ In Order To Ensure The Safety Of The Operator, The Power Outlet In The Laboratory Should Be Grounded Reliably;.
Features
- The Viscosimeters should be placed on a strong and smooth surface away from strong airflow, strong magnetic field, strong electric field and strong electric pulse interference.
- In order to ensure the safety of the operator, the power outlet in the laboratory should be grounded reliably;
- The temperature in the laboratory should be 23 C + 2 C, and the relative humidity should be less than 75%.
- The stom Viscosimeters is used for the determination of paint and other KU indicating the viscosity of the coating. The instrument can display the KU value of the measured sample viscosity or the load value associated with the KU value (unit: G).
- See more on Amazon...
Brand: CNYST | Manufacturer: CNYST
Weight: 22.05 Pounds
See On Amazon #4
CNYST Stormer Viscometer Stormer Type Viscosity Meter with Measurement Range 40.2~141.0KU for The Determination of Paint and Other KU Indicating The Viscosity of The Coating
Asin: B0D1V9LSNK | Model: 2024401605 | PartNumber: 2024401605
◆ The Temperature In The Laboratory Should Be 23 °C + 2 °C, And The Relative Humidity Should Be Less Than 75%..
◆ The Stom Viscosimeters Is Used For The Determination Of Paint And Other Ku Indicating The Viscosity Of The Coating. The Instrument Can Display The Ku Value Of The Measured Sample Viscosity Or The Load Value Associated With The Ku Value (Unit: G)..
◆ In Order To Ensure The Safety Of The Operator, The Power Outlet In The Laboratory Should Be Grounded Reliably;.
Features
- The Viscosimeters should be placed on a strong and smooth surface away from strong airflow, strong magnetic field, strong electric field and strong electric pulse interference.
- In order to ensure the safety of the operator, the power outlet in the laboratory should be grounded reliably;
- The temperature in the laboratory should be 23 C + 2 C, and the relative humidity should be less than 75%.
- The stom Viscosimeters is used for the determination of paint and other KU indicating the viscosity of the coating. The instrument can display the KU value of the measured sample viscosity or the load value associated with the KU value (unit: G).
- See more on Amazon...
Brand: CNYST | Manufacturer: CNYST
Weight: 22.05 Pounds
See On Amazon #5
VTSYIQI Stormer Viscosity Tester Digital Stormer Viscometer Paint Viscosity Meter with Range 40.2 to 141.0KU Accuracy 2.00% KU CP G Temp Display LCD Digital Display
Asin: B0D1TX1F2P | Model: VTSYIQI20240416141919VTSYIQI | PartNumber: VTSYIQI20240416141919VTSYIQI
★Operation---1. Remove The Instrument From The Packaging Box And Put It On The Worktable. 2. Remove The Stirring Blade From The Packing Box, Insert It Into The Sleeve Of The Rotating Shaft, And Fix It With The Top Tightening Screw. 3. Plug In The Power Plug, Open The Power Switch On The Back, The System Starts To Self Check, The System Will Enter The Standby State After The Completion Of The Self Test, And The Display Will Display "-". 4. Put The Tested Sample In The Container.
★ Note---1. There Are Precise Measuring Parts In The Instrument Cabinet. 2. This Instrument Is A Special Instrument. Please Do Not Open The Instrument Shell By Itself, So As Not To Affect The Accuracy Of Instrument Measurement. 3. Instruments Are Temporarily Unused, The Lifting Handle Of The Instrument Should Be Kept On The High Position Limit Unit, And It Should Not Be Placed In A Lower Position, Otherwise The Phenomenon Of Inflexibility May Be Produced. 4. Every Year, Companies Should Be Check.
★ Use---6. After A Few Seconds, The Monitor Displays The Viscosity Value Of The Sample To Be Measured, Which Can Be Read At This Time. (The Sample Must Be Stirred For A Few Seconds To Achieve Dynamic Balance, And The Data Displayed Can Be Considered Accurate, Without The Display Of The Data Before The Instrument "--"). 7. After The Measurement Is Completed, The Lifting Handle Is Lifted To The Height, And There Is A Limited Bit Device Near The Highest Position.
★The Main Technical Parameters---1. Measurement Range: 40.2 ~ 141.0Ku (Ku Value), 27Cp-5250Cp 32 ~ 1099G (Load Value); 2. Measurement Accuracy: 2.0% Of Full Range; 3. Measurement Repeatability: The Full Range Of 2.0%; 4. The Rotational Speed Of The Mixing Axis: 200R/Min + 1R/Min; 5. Container Capacity: About 500Ml; 6. Input Voltage: 220V 50Hz; 7. Power: 10W; 8. Shape Size: 210Mm X 180Mm X 500Mm (Long * Width *); 9. Weight: 10Kg..
Features
- Summary---The instrument is controlled by a computer. The blade of a stirred blade (also called a rotor) is driven by a constant speed motor at a speed of 200r/min. The resistance moment of the impeller in the measured sample is converted by a computer to the KU value. unit (KU) is a logarithmic function of the load required to produce 200r/min speed, which is generally used to represent the speed of the 200r/min. It is used for the viscosity of the brush and roll.
- The main technical parameters---1. measurement range: 40.2 ~ 141.0KU (KU value), 27cP-5250cP 32 ~ 1099g (load value); 2. measurement accuracy: 2.0% of full range; 3. measurement repeatability: the full range of 2.0%; 4. the rotational speed of the mixing axis: 200r/min + 1r/min; 5. container capacity: About 500ml; 6. input voltage: 220V 50Hz; 7. power: 10W; 8. shape size: 210mm x 180mm x 500mm (long * width *); 9. weight: 10kg.
- Operation---1. remove the instrument from the packaging box and put it on the worktable. 2. remove the stirring blade from the packing box, insert it into the sleeve of the rotating shaft, and fix it with the top tightening screw. 3. plug in the power plug, open the power switch on the back, the system starts to self check, the system will enter the standby state after the completion of the self test, and the display will display -. 4. put the tested sample in the container
- Use---6. after a few seconds, the monitor displays the viscosity value of the sample to be measured, which can be read at this time. (the sample must be stirred for a few seconds to achieve dynamic balance, and the data displayed can be considered accurate, without the display of the data before the instrument --). 7. after the measurement is completed, the lifting handle is lifted to the height, and there is a limited bit device near the highest position
- Note---1. there are precise measuring parts in the instrument cabinet. 2. this instrument is a special instrument. Please do not open the instrument shell by itself, so as not to affect the accuracy of instrument measurement. 3. instruments are temporarily unused, the lifting handle of the instrument should be kept on the high position limit unit, and it should not be placed in a lower position, otherwise the phenomenon of inflexibility may be produced. 4. every year, companies should be check
- See more on Amazon...
Brand: VTSYIQI | Manufacturer: VTSYIQI20240416141919VTSYIQI
Dimensions: 5.91 x 3.94 x 13.78 inches
See On Amazon #6
CNYST Integrated Leeb Hardness Tester Meter Durometer with Type C Impact Device Range HLC 170-960 for Testing The Hardness of Surface Hardening Layers and Parts with Small Mass or Thin Thickness
Asin: B0BLNGP54F | Ean: 0721553982116 | UPC: 721553982116
3. The Instrument Can Be Measured In 360 ° At All Angles, The Probe Built-In Direction Sensor, Can Automatically Compensate For The Measurement Error Of Different Impact Directions, Multi-Angle Measurement Easily And Worry-Free..
5. The Instrument Has 10 Kinds Of Built-In Metal Materials, Including Steel, Alloy Tool Steel, Stainless Steel, Gray Cast Iron, Etc., With A Wide Range Of Applications And Industries Involved To Meet Daily Work Requirements..
4. Instrument Built-In A Variety Of Hardness System, Can Be In The Richter (Hl), Vickers (Hv), Brinell (Hb), Shore (Hs), Rockwell (Hrc) Conversion Between Each Other. Instrument Internal Directly Help You Convert Data, No Manual Calculation..
2. Adopting Double Coil Technology And With Advanced Timing Chip, The Instrument Has High Measurement Accuracy And Good Repeatability..
Features
- 1. The instrument adopts C-type impact device with low impact force, suitable for testing metal parts with small mass or thin thickness and surface hardening layer.
- 2. Adopting double coil technology and with advanced timing chip, the instrument has high measurement accuracy and good repeatability.
- 3. The instrument can be measured in 360 at all angles, the probe built-in direction sensor, can automatically compensate for the measurement error of different impact directions, multi-angle measurement easily and worry-free.
- 4. Instrument built-in a variety of hardness system, can be in the Richter (HL), Vickers (HV), Brinell (HB), Shore (HS), Rockwell (HRC) conversion between each other. Instrument internal directly help you convert data, no manual calculation.
- 5. The instrument has 10 kinds of built-in metal materials, including steel, alloy tool steel, stainless steel, gray cast iron, etc., with a wide range of applications and industries involved to meet daily work requirements.
- See more on Amazon...
Brand: CNYST | Manufacturer: CNYST
Dimensions: 0.94 x 7.99 x 1.34 inches | Weight: 3.31 Pounds
See On Amazon #7
CNYST Stormer Viscometer Viscosity Meter for Paint with Measurement Range 40.2 to 141.0KU Accuracy 1.50% of Full Range
Asin: B07MNL16Y8 | Model: Viscosímetro | PartNumber: Viscosímetro | Ean: 0652054888761 | UPC: 652054888761
◆ The Temperature In The Laboratory Should Be 23 °C + 2 °C, And The Relative Humidity Should Be Less Than 75%..
◆ The Stom Viscometer Is Used For The Determination Of Paint And Other Ku Indicating The Viscosity Of The Coating. The Instrument Can Display The Ku Value Of The Measured Sample Viscosity Or The Load Value Associated With The Ku Value (Unit: G)..
◆ In Order To Ensure The Safety Of The Operator, The Power Outlet In The Laboratory Should Be Grounded Reliably;.
Features
- The instrument should be placed on a strong and smooth surface away from strong airflow, strong magnetic field, strong electric field and strong electric pulse interference.
- In order to ensure the safety of the operator, the power outlet in the laboratory should be grounded reliably;
- The temperature in the laboratory should be 23 C + 2 C, and the relative humidity should be less than 75%.
- The stom viscometer is used for the determination of paint and other KU indicating the viscosity of the coating. The instrument can display the KU value of the measured sample viscosity or the load value associated with the KU value (unit: G).
- See more on Amazon...
Brand: CNYST | Manufacturer: CNYST
Dimensions: 19.69 x 8.27 x 7.09 inches | Weight: 28.66 Pounds
See On Amazon #8
CNYST Digital Lab Stormer Viscometer Viscosity Testing Equipment Machines Measuring for Paint Coating with 5 inch Touch Screen Range 40.2KU -141.0KU/ 32g-1099g/ 27-5250CP
Asin: B07MCXCDL2 | Model: Viscosímetro | PartNumber: Viscosímetro | Ean: 0652054889126 | UPC: 652054889126
◆ Measurement Accuracy: ±1%(Full Range); Measuring Container:400Ml.
◆Various Parameters And Working Conditions Can Be Completely And Directly Displayed On The 5 Inch Ultra-Large Colorful Touch Screen. Various Parameters Can Be Measured, Displayed And Read Directly In High Accuracy, The Instrument Can Be Displayed Conveniently..
◆ Measurement Accuracy: ±1%(Full Range); Measuring Container:400Ml.
◆ Control/Display Mode: 5 Inch Colorful Touch Screen; Rotating Speed: 200±0.1Rpm/Min.
Features
- Stormer Viscometer: Touch screen viscometer is perfectly integrated with the touch screen technology, and the viscosity can be measured with a fashion, modern and high technology rapidly, accurately and directly.
- Control/Display mode: 5 inch colorful touch screen; Rotating speed: 200 0.1RPM/min
- Measurement accuracy: 1%(full range); Measuring container:400ml
- Measurement accuracy: 1%(full range); Measuring container:400ml
- Various parameters and working conditions can be completely and directly displayed on the 5 inch ultra-large colorful touch screen. Various parameters can be measured, displayed and read directly in high accuracy, the instrument can be displayed conveniently.
- See more on Amazon...
Brand: CNYST | Manufacturer: CNYST
Dimensions: 17.72 x 11.81 x 11.81 Inches | Weight: 24.25 pounds
See On Amazon
Looking For Something Else?
Search